APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21322 Issued:2004-03-01
Revised:2011-12-16
Style 21322 Multiconductor Cable with Extruded Non-Integral Jacket

Rating60 deg C, 90 Vac, Horizontal flame.
InsulationLabeled or complies with manufacturer's Procedure.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together or groups may be laid parallel to form flat, oval, or round cables. May use same or mixed AWG. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
CoveringOptional.
ShieldOptional.
JacketExtruded TPU, 15 mils min average, 12 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024