Rating | 60 deg C, 300 Vac, Cable flame. |
|
Insulation | Labeled or complies with manufacturer's AWM Procedure. |
|
Assembly | Two or more singles, twisted pair, or more twisted pairs, or mixture of them, and optic fiber members which employ Nylon covering, minimum 5 mils, over glass fiber optic core are wrapped around a strength member composed of stranded steel wires. Barrier layer, fillers and/or core wrap optional. May use same or mixed AWG sizes. Manufacturer shall maintain a complete description of each assembly. Calculated diameter of round assembly under jacket should be less than 0.700 inch. |
|
Shield | Optional. |
|
Jacket | Extruded PVC, 40 mils min average, 32 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment.The tag must additionally indicate "Centrally located steel strands wire is a strength member and not for current carrying purpose, it should never be connected to other than Ground". |
|