APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2135 Issued:1959-05-01
Revised:2011-08-04
Style 2135 Parallel Cable with Extruded Integral Insulation and Jacket

Rating60 deg C, 300 Vac, Horizontal flame
Conductor21 AWG solid or stranded
InsulationPVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point
AssemblyTwo or three conductors, same as type SPT-1
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseElectric Heating Pad connections or Electric Bed Covering connections.