APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21353 Issued:2004-05-12
Revised:2012-04-18
Style 21353 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 30 Vac, Cable flame.
Conductor40 AWG minimum.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyConsists of two or more insulated conductors, twisted pairs or groups of twisted insulated conductors twisted together. The insulated conductors or groups of insulated conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors is not specified. Barrier layers and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
JacketPUR.
Diameter of cable under jacketMinimum averageMinimum at any point
0.250 inch or less15 mils12 mils
0.251-0.425 inch30 mils27 mils
0.426-0.700 inch45 mils36 mils
0.701-1.000 inch60 mils48 mils
1.001-1.500 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or External interconnection of electronic equipment, Class 2 Circuits only.