APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21365 Issued:2004-07-05
Revised:2012-03-27
Style 21365 Flat parallel cord.

Rating105 deg C, 300 Vac, FT2 flame.
Conductor18 AWG - 10 AWG, stranded.
InsulationExtruded PVC.
Conductor AWG SizeMinimum avergae thickness milsMinimum thickness at any point mils
18-123027
104540
AssemblyFour insulated circuit conductors and one insulated grounding conductor laid parallel. Configuration the same as for Type SPT-3.
ShieldRequired.
JacketExtruded PVC.
Conductor AWG sizeMinimum average thickness milsMinimum thickness at any point mils
18-163024
145040
12-106552
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor use where:-Type SPT-3 or equivalent is required;-Metallic shielding is required around the insulated conductors;-An insulation grade (300 V rated) jacket is required.