Rating | 80 deg C, 90 Vac, Horizontal flame. |
|
Conductor | 32 AWG minimum, solid or stranded. |
|
Insulation | Labeled or complying with Manufacturer's AWM Procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a round cable. The lay of the conductor is not specified. A Braid are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Coated Copper Braid. |
|
Covering | PVC tape, 9 mils min thickness. |
|
Jacket | Extruded PVC |
| major dia. in inches |
| 0.200 or less | 38 mils min average | 30 mils minimum at any point |
| 0.201-1.000 dia | 45 avg | 36 min |
| 1.001-1.500 dia | 60 avg | 48 min |
| 1.501-2.500 dia | 80 avg | 64 min |
| 2.501 dia and larger | 110 avg | 88 min |
|
Misc. | Tape - Extruded PVC (minimum thickness 0.023 mm). Drain Wire - (Optional) Stranded. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal or external wiring of electronic equipment and appliances. |
|