Rating | 80 deg C, 90 Vac, Horizontal flame. |
|
Conductor | 32 AWG minimum, solid or stranded. |
|
Insulation | Labeled or complying with Manufacturer's AWM Procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a round cable. The lay of the conductor is not specified. A Braid is optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Coated Copper Braid. |
|
Misc. | Tape - Extruded PVC, 0.023 mm minimum thickness. Drain Wire - Optional, Stranded. |
|
Jacket | Extruded PUR |
| Diameter of core assembly under jacket* | Minimum average thickness | Minimum thickness at any point |
| 0.200 inch or less | 38 mils | 30 mils |
| 0.201-1.000 inch | 45 mils | 36 mils |
| 1.001-1.500 inch | 60 mils | 48 mils |
| 1.501-2.500 inch | 80 mils | 64 mils |
| 2.501 inch and larger | 110 mils | 88 mils |
| * - Major dia if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal or external wiring of electronic equipment and appliances. |
|