APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2137 Issued:1959-05-01
Revised:2012-02-09
Style 2137 Parallel Cable with Extruded Integral Insulation

Rating80 deg C, 300 Vac, FT2 flame. Optional - 60 or 80 deg C Oil.
Conductor18 and 16 AWG stranded, consisting of 30 AWG or smaller strands.
InsulationExtruded PVC, 60 mils minimum average thickenss.
AssemblyFour conductors, consisting of three 18 AWG and one 16 AWG. Same as type SPT-2 except for the following minimum (pin gauge) dimensions: Wall thickness: 58 mils; Web thickness: 78 mils; Wall thickness after rip: 28mils.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electric refrigerators where ripped not more than 3 inches and where exposed to temperatures not exceeding 80 deg C. May add where applicable dependent upon the compound used: and where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable). Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024