APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21371 Issued:2004-06-16
Revised:2011-10-26
Style 21371 Multiconductor cable with extruded non-integral jacket.

Rating80 deg C, 30 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors or groups of conductors twisted together. The conductors or groups of conductors may be laid to form an oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly.
BraidCopper, tinned or bare.
JacketExtruded TPE.
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.400 inch or less24 mils20 mils
0.401-0.700 inch30 mils24 mils
0.701-1.500 inch45 mils36 mils
1.501-2.500 inch60 mils48 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024