Subj.758 Section 2 Page 21381 Issued:2004-07-28
Revised:2019-11-07
Style 21381 Multiple conductor cable using non-integral jacket.

Rating90 deg C, 600 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Overall Assembly - The TPE Jacket extends to form a Web 750 mils wide between conductors; Web Minimum Average thickness and the Minimum Thickness at any point is an extension of the Jacket Thickness. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
BraidOptional
JacketTPE
major dia. in inches
0.700 or less30 mils min average24 mils minimum at any point
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min
1.501-2.500 dia80 avg64 min
2.501-4.000 dia110 avg88 min
4.001 dia and larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring and/or external interconnection.