APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21383 Issued:2004-08-12
Revised:2012-03-30
Style 21383 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating80 deg C, 300 Vac, Cable flame.
Conductor32 AWG - 10 AWG solid or stranded round, tinned or bare.
InsulationExtruded PP (Polypropylene)
AWG Conductor SizeMinimum average thickness (mils)Minimum thickness at any point (mils)
32-2086.5
18-16108.5
14-101210
AssemblyTwo to Six Conductors
ShieldFoil Wrap and Braid
JacketExtruded FRPE
Diameter of core assembly under jacket (inches)Minimum average thickness (mils)Minimum thickness at any point (mils)
0.700 or less3024 nt
0.701-1.0004536
1.010-1.5006048
1.501-2.5008064
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or External Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024