APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21384 Issued:2004-08-12
Revised:2011-08-11
Style 21384 Multiple-Conductor Cable with Extruded Non-Integral Jacket

Rating150 deg C, 600 Vac, Horizontal flame
Conductor30 AWG - 2 AWG solid or stranded
InsulationLabeled or complying with the manufacturer's AWM Procedure
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size
JacketExtruded PFA, 20 mils minimum average thickness, 16 mils minimum thickness at any point
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseInternal wiring of appliances or electronic equipment