APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21385 Issued:2004-08-12
Revised:2012-05-07
Style 21385 Multiple conductor using non-integral jacket

Rating200 deg C, 600 Vac, Horizontal flame.
Insulated conductorsNos. 30-2 AWG, Labeled or complying with the manufacturer's AWM Procedure having a minimum rating of 200 deg C and 600 V.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
JacketPFA, 20 mils minimum average thickness, 16 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of appliances or electronic equipment