Rating | 105 deg C, 300 Vac, FT2 flame, Oil Resistant 60 deg C or 80 deg C (optional). |
|
Conductor | Three No. 18 AWG and one No. 16 AWG, using No. 30 AWG, or smaller tinned or bare copper strands. |
|
Insulation | Integral with Jacket. Extruded PVC, 60 mils min average, 54 mils minimum at any point. |
|
Assembly | Four conductors, same as type SPT-2 except for a nominal 60 mil, the following minimum (pin gauge) dimensions: Wall thicknes: 0.058 in., Web thickness: 0.078 in., Wall after rip: 0.028 in.. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electric refrigerators where ripped not more than 3 inches and where exposed to temperatures not exceeding 105 deg C. May add where applicable dependent upon the compound used: and where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable). Polarity identification may be omitted. |
|