APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21390 Issued:2004-10-11
Revised:2011-10-19
Style 21390 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 30 Vac, Horizontal flame.
InsulationLabeled or complies with manufacturer's AWM Procedure.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together or groups may be laid parallel to form flat, oval, or round cables. May use same or mixed AWG. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
JacketPUR, 16 mils min average, 13 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring in Class 2 circuits of electronic equipment; or as Telephone Handset Cord.

UL and the UL Logo are trademarks of UL LLC © 2024