Rating | 80 deg C, 30 Vac, Cable flame. |
|
Conductor | 40 AWG minimum. |
|
Insulation | Labeled or complying with Manufacturer's AWM Procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs, parallel pairs, or groups of twisted conductors or parallel pairs twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Covering | Optional. Optional. Extruded FRPE, 6 mils minimum at any point, applied over the conductor assembly. |
|
Jacket | PVC. |
| Construction A External Use | | Construction B Internal Use | |
| Dia of cable under jacket | Minimum average | Minimum at any point | Minimum average | Minimum at any point |
| 0.350 inch or less | 20 mils | 17 mils | 15 mils | 12 mils |
| 0.351-0.700 inch | 30 mils | 24 mils | 30 mils | 24 mils |
| 0.701-1.000 inch | 40 mils | 32 mils | 40 mils | 32 mils |
| 1.001-1.500 inch | 54 mils | 43 mils | 54 mils | 43 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Construction A: Internal wiring or external interconnection of electronic equipment in Class 2 circuit only.Construction B: Internal wiring of electronic equipment in Class 2 circuit only. |
|