APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21392 Issued:2004-10-11
Revised:2012-02-20
Style 21392 Multiconductor Cable with Extruded Non-Integral Jacket.

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded.
InsulationLabeled or complies with manufacturer's AWM Procedure.
AssemblySingles or groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional.
CoveringExtruded PVC, 12 mils minimum average, 10 mils at any point.
ShieldOptional.
JacketExtruded TPU, 12 mils min average, 10 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024