APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21399 Issued:2005-02-02
Revised:2011-09-26
Style 21399 Multiconductor Cable With Extruded Non-Integral Jacket

Rating105 deg C, 300 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs or groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval, or round cables. May use same or mixed AWG size. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOptional.
JacketExtruded XLPE, 7 mils minimum average thickness, 5 mils minimum thicknessat any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024