APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21401 Issued:2005-02-02
Revised:2012-03-30
Style 21401 Multi-conductor cable using non-integral jacket

Rating125 deg C, 30 Vac Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs or groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval, or round cables. May use same or mixed AWG size. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOptional.
JacketExtruded XLPE, 7 mils min average, 5 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.