APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21412 Issued:2005-02-02
Revised:2011-09-20
Style 21412 Jacketed Cable.

Rating125 deg C, 600 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure with minimum rating of 125?C, 600 V.
AssemblyTwo or more singles, twisted pairs or groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval, or round cables. May use same or mixed AWG size. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOptional.
JacketXLPE
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring and external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024