APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21425 Issued:2005-02-28
Revised:2012-04-26
Style 21425 Multiple-Conductor Cable using Non-Integral Jacket

Rating80 deg C, 30 Vac, Horizontal flame.
InsulationLabeled or complies with manufacturer's AWM Procedure.
AssemblyInsulated singles, twisted pairs or members of conductor assembly cabled together to form a round cable; two to four insulated singles, twisted pairs or members of conductor assembly may be laid parallel to form an oval or flat cable.Use of fillers, barriers optional. May use same or mixed AWG size. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
JacketExtruded FRPE, 10 mils min average, 8 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.