Rating | 80 deg C, 150 Vac, Horizontal flame. |
|
Conductor | 40 AWG - 31 AWG. Inner - spirally wound over a fiber core, 70 - 10 turns per inch. Middle - spirally wound over Inner Insulation, 70 - 10 turns per inch. Outer - spirally wound over Middle Insulation, 70 - 10 turns per inch. |
|
Insulation | Integral with Jacket. Inner and middle insulation - extruded PVC, 6 mils minimum average thickness, 5 mils minimum thickness at any point. Outer insulation - extruded PVC, 16 mils minimum average thickness, 14 mils minimum thickness at any point. |
|
Assembly | A fiber core wrappped with inner conductor, inner insulation, middle conductor, middle insulation, outer conductor and outer insulation. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. |
|