APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21432 Issued:2005-03-18
Revised:2012-03-13
Style 21432 Multiple-conductor cable using non-integral jacket.

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor18 AWG - 10 AWG. Solid or stranded.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo to more conductors with overall jacket.
JacketExtruded TPE.
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
1.000 or less inch45 mils36 mils
1.001-1.600 inch60 mils48 mils
1.601-2.500 inch80 mils64 mils
2.501-4.000 inch110 mils88 mils
4.001 and larger inch140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024