Rating | 60 or 80 deg C, Voltage not specified, Horizontal flame. |
|
Inner Conductor | 12 AWG consists of twenty-two bundled wires with a minimum diameter of 5.8 mm. Each bundle consists of thirty-six strands of 0.07 mm diameter. Outer Conductor - 1 AWG consists of thirty bundled wires. Each bundle consists of 129 strands of 0.05 mm diameter. |
|
Tape | PTFE 2 mils (0.056 mm) thick.
|
|
Insulation | Inner - TPE, 15 mils min average, 13 mils minimum at any point. |
|
Outer Conductor | 1 AWG consists of 30 bundled wires served over the insulation. Each bundle consists of 129 strands of 0.05 mm diameter. |
|
Tape | PTFE 2 mils (0.056 mm) thick.
|
|
Insulation | Outer - PVC, 15 mils min average, 13 mils minimum at any point. |
|
Shield | Optional, applied over the core with a minimum 85% coverage. |
|
Tape | PTFE 2 mils (0.056 mm) thick.
|
|
Jacket | PVC, Inner - 15 mils min average, 13 mils minimum at any point. |
|
Outer Shield | Optional, applied over the core with a minimum 85% coverage. |
|
Tape | Optional. PTFE 2 mils (0.056 mm) thick.
|
|
Overall Jacket | PVC, 27 mils min average, 21 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal interconnection of electronic equipment or for further processing in jacketed cables. |
|