APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2145 Issued:1959-05-01
Revised:2012-04-18
Style 2145 Multiple-conductor using non-integral jacket.

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor18 AWG - 16 AWG, stranded.
InsulationExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
AssemblyFive conductors, same as Type SVT.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electric fans.

UL and the UL Logo are trademarks of UL LLC © 2024