APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21454 Issued:2005-09-30
Revised:2011-11-28
Style 21454 Multiconductor cable with extruded non-integral jacket.

Rating60 deg C, 30 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturers procedure.
AssemblyTwo or more insulated conductors.
CoveringOptional.
ShieldOptional.
JacketExtruded mPPE-PE
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.250 inch or less15 mils12 mils
0.251-0.424 inch30 mils24 mils
0.425-0.700 inch60 mils48 mils
0.701-1.500 inch80 mils64 mils
1.501-2.500 inch110 mils88 mils
2.501 inch and larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring in Class 2 circuits and both ends are terminated in connectors.

UL and the UL Logo are trademarks of UL LLC © 2024