APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21455 Issued:2005-09-30
Revised:2011-09-19
Style 21455 Multiconductor Cable with Extruded Non-Integral Jacket

Rating80 deg C, 30 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM Procedure with minimum rating of 80 deg C, 30 Vac.
AssemblyTwo or more insulated conductors.
CoveringOptional.
ShieldOptional.
JacketExtruded mPPE-PE
Diameter of core assembly under jacket*Minimum average thicknessMinimum thickness at any point
0.350 inch or less15 mils12 mils
0.351-0.700 inch30 mils24 mils
0.701-1.000 inch40 mils32 mils
1.101-1.500 inch54 mils43 mils
*Equivalent diameter of flat assembly = 1.1284 x (TW)^0.5 where T is the thickness of the assembly under jacket, and W is the width of the assembly under jacket.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.