APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21456 Issued:2005-09-30
Revised:2011-10-26
Style 21456 Multiconductor cable with extruded non-integral jacket

Rating80 deg C, 30 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturers procedure.
AssemblyTwo or more insulated conductors.
CoveringOptional.
ShieldOptional.
JacketExtruded mPPE-PE.
Diameter of core assembly under jacket *Minimum average thicknessMinimum thickness at any point
0.250 inch or less15 mils12 mils
0.251-0.350 inch22 mils18 mils
0.351-0.424 inch30 mils24 mils
0.425-0.700 inch60 mils48 mils
* - Equivalent diameter of flat assembly = 1.1284 X (TW)^0.5. Where T is the thickness of the assembly under jacket, and W is the width of the assembly under jacket.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring in Class 2 circuits and both ends are terminated in connectors.