APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2146 Issued:1959-05-01
Revised:2011-10-24
Style 2146 Multiple-conducotr cable using extruded non-integral jacket.

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor18 AWG, stranded.
InsulationExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
AssemblySix conductors, same as Type SVT.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024