APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21464 Issued:2005-11-15
Revised:2011-08-11
Style 21464 Multiple-Conductor Cable with Extruded Non-Integral Jacket

Rating60 deg C, 30 Vac, Cable flame
Conductor50 AWG - 2000 kcmil solid or stranded
InsulationLabeled or complies with Manufacturers AWM Procedure
AssemblyTwo or more insulated singles or groups of insulated singles cabled together to form a flat, oval or round assembly. Barrier layer and/or fillers optional. May use same or mixed AWG size.
ShieldOptional
JacketExtruded TPE
@Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
2.501-4.000 inch110 mils88 mils
4.001 inch and larger140 mils112 mils
@ - Major diameter if cable is flat or oval
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseInternal Wiring and External Interconnection