APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21465 Issued:2005-11-18
Revised:2012-05-07
Style 21465 Multiple Cable using non-integral jacket

Rating90 deg C, 1000 Vac, Horizontal flame.
Conductor30 AWG - 2000 kcmil, solid or stranded, tinned or bare copper.
Insulated SingleLabeled or complying with Manufacturer's AWM Procedure.
CoveringInner - (Optional) 4 mil or heavier wall EPDM may be extruded over the conductor assembly or groups of conductors. Outer - (Optional) 1 mil or heavier PETP foil covering may be applied over the conductor assembly.
ShieldOptional
JacketEVA
dia. in inches under the jacket
0.750 or less55 mils min average44 mils minimum at any point
0.751-1.000 dia110 avg88 min
1.001-1.250 dia125 avg100 min
1.251-1.500 dia140 avg112 min
1.501-1.750 dia160 avg128 min
1.751-2.000 dia180 avg144 min
2.001-2.250 dia200 avg160 min
2.251-2.500 dia220 avg176 min
2.501-2.750 dia240 avg192 min
2.751-3.000 dia260 avg208 min
3.001-3.250 dia280 avg224 min
3.251-3.500 dia295 avg236 min
3.501-3.950 dia310 avg248 min
3.951-4.450 dia330 avg264 min
4.451-5.000 dia345 avg276 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.