APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21466 Issued:2005-11-18
Revised:2019-11-07
Style 21466 Multiconductor Cable with Extruded Non-Integral Jacket

Rating80 deg C, 300 Vac, Horizontal flame.
ConductorNo. 32 AWG minimum, solid or stranded round, tinned or bare copper.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional. A 6 mil or heavier covering may be extruded over the conductor assembly.
JacketTPU
dia. in inches
0.700 or less35 mils min average28 mils minimum at any point
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min
1.501-2.500 dia80 avg64 min
2.501-4.000 dia110 avg88 min
4.001 dia and larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.