APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21467 Issued:2005-11-18
Revised:2019-11-07
Style 21467 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 300 Vac, Cable flame.
Conductor32 AWG - 4/0 AWG, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional.
BraidOptional.
JacketExtruded PVC
dia. in inches
0.700 or less35 mils minimum average thickness28 mils minimum thickness at any point
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min
1.501-2.500 dia80 avg64 min
2.501-4.000 dia110 avg88 min
4.001 dia and larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024