APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21483 Issued:2006-02-20
Revised:2019-11-07
Style 21483 Multiple conductor cable using extruded non-integral jacket

Rating80 deg C, 1000 Vac, Horizontal flame.
Conductor36 AWG minimum solid or stranded.
InsulationLabeled or complying with manufacturers AWM Procedure.
AssemblyTwo or more insulated singles or groups of insulated singles cabled together to form a flat, oval or round assembly. Barrier layer and/or fillers optional. May use same or mixed AWG size. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOptional.
BraidOptional.
JacketExtruded TPE
major dia. in inches
0.700 or less45 mils min average36 mils min at any point
0.701-1.000 dia6048
1.001-1.500 dia8064
1.501-2.500 dia11088
2.500 dia and larger140112
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.