| Rating | 90 deg C, 600 Vac, Horizontal flame. |
|
| Conductor | 36 AWG min. solid or stranded. |
|
| Insulation | Labeled or complying with manufacturers AWM Procedure. |
|
| Assembly | Two or more insulated singles or groups of insulated singles cabled together to form a flat, oval or round assembly. Barrier layer and/or fillers optional. May use same or mixed AWG size. Manufacturer shall maintain a complete description of each assembly. |
|
| Covering | Optional. |
|
| Shield | Optional. |
|
| Jacket | Extruded TPE |
| dia. of core assembly under jacket | minimum average thickness | minimum thickness at any point |
| 0.700 inch or less | 45 mils | 36 mils |
| 0.701-1.000 inch | 60 mils | 48 mils |
| 1.001-1.500 inch | 80 mils | 64 mils |
| 1.501-2.500 inch | 110 mils | 88 mils |
| 2.500 inch and larger | 140 mils | 112 mils |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring of electronic equipment and appliances. |
|