Rating | 150 deg C, 300 Vac, Horizontal flame (construction A only). |
|
Conductor | 36 AWG - 20 AWG solid or stranded. |
|
Assembly | Two to six individually insulated conductors or groups of conductors cabled together into a round cable. Lay not specified. |
|
Insulation | Extruded ETFE, 9 mils min average, 8 mils min at any point. |
|
Shield | Aluminum polyester tape shield, min 10% overlap, 1.0 mils min, with drain wire. |
|
Covering | Construction A: Extruded FR XLPE, 9 mils min avg. thickness, 7 mils min thickness at any point. Construction B: Extruded XLPE, 9 mils minimum average thickness, 7 mils min. thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | CONSTRUCTION A: Internal Wiring, High Resistance Heater Wire.
CONSTRUCTION B: For Further Processing, High Resistance Heater Wire. |
|