APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21488 Issued:2006-02-24
Revised:2012-03-30
Style 21488 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor50 AWG - 10 AWG solid or stranded round, tinned or bare.
InsulationExtruded Foamed XLPE, 23 mils minimum average thickness, 21 mils minimum thickness at any point.
AssemblyTwo or more conductors.
ShieldOptional. Spiral wrapped strands.
JacketExtruded PVC, 12 mils minimum average thickness, 10 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.