APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2149 Issued:1959-05-01
Revised:2012-07-03
Style 2149 Parallel Cable with Extruded Integral Insulation and Jacket.

Rating80 deg C, 300 Vac, FT2 flame, Oil Resistant 60 deg C or 80 deg C (optional).
Conductor20 AWG consisting of No. 30 AWG or smaller.
InsulationIntegral with Jacket. Extruded PVC, 60 mils mininum average thickness, 54 mils minimum thickness at any point, with the following minimum (pin gauge) dimensions: Web thickness: 0.070 in., Wall after rip: 0.028 in..
AssemblyTwo conductors, same as type SPT-2
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electric refrigerators where installed within separate metal enclosures or between the walls of the cabinet, and where exposed to temperatures not exceeding 80 deg C. Dependent upon the compound used, the tag may add: and where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable). Polarity identification may be omitted.