APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21493 Issued:2006-04-14
Revised:2011-10-28
Style 21493 Flat Cable.

Rating80 deg C, 30 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more insulated conductors.
ShieldOptional.
CoveringInner - Optional. Outer - Foamed PTFE tape bonded each side with FEP adhesive, 2 mils minimum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.