APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21495 Issued:2006-04-14
Revised:2012-02-06
Style 21495 Multiple-conductor with other-than-extruded covering

Rating80 deg C, 600 Vac, Horizontal flame.
InsulationLabeled or comply with manufacturer's AWM Procedure.
AssemblyTwo or more insulated conductors.
ShieldOptional.
CoveringInner - Optional. Outer - Foamed PTFE tape bonded each side with FEP adhesive, 2 mils minimum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.