APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21502 Issued:2006-07-18
Revised:2011-10-20
Style 21502 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 30 Vac, Cable flame.
Insulated ConductorLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwisted assembly of two or more conductors, twisted pairs, or groups of precabled conductors, or Assembly may be parallel laid of conductors, twisted pairs, or groups of precabled conductors forming a flat or oval cable.The length of lay of the insulated conductors or groups of conductors not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of the assembly.
CoveringOptional.
ShieldOptional.
JacketExtruded mPPE-PE
Dia. Of core assembly under jacketMin average thicknessMin thickness at any point
1.500 inch or less20 mils16 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal or external wiring in Class 2 circuits only.

UL and the UL Logo are trademarks of UL LLC © 2024