APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21512 Issued:2006-09-05
Revised:2012-03-30
Style 21512 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating105 deg C, 1000 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more insulated conductors.
ShieldOptional.
CoveringOptional.
JacketExtruded MPPE
Diameter of core assembly under jacket (inches)Minimum average thickness (mils)Minimum thickness at any point (mils)
0.700 or less*3024
0.701-1.0004536
1.001-1.5006048
1.501-2.5008064
*Equivalent diameter of flat assembly = 1.1284 x (TW)0.5 where T is the thickness of the assembly under jacket, and W is the width of the assembly under jacket
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring and external wiring.