APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21526 Issued:2006-11-13
Revised:2018-03-07
Style 21526 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 150 Vac Cable flame.
Conductor40 AWG - 2000 kcmil, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together to form a round cable. A flat or oval cable may also be constructed with not more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; thermoplastic covering or thermoplastic tape wrap. The barrier layer may be applied over the twisted assembly of individual conductors, groups of conductors or individual conductors or over the shield, if provided.
ShieldOptional.
JacketExtruded TPU
dia. of core assembly under jacketmin averageminimum at any point
0.700 inches or less30 mils24 mils
0.701-1.000 dia45 mils36 mils
1.001-1.500 dia60 mils48 mils
1.501-2.500 dia80 mils64 mils
2.501-4.000 dia110 mils88 mils
4.001 dia and larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment. or Internal wiring or external interconnection of electronic equipment in abuse areas.

UL and the UL Logo are trademarks of UL LLC © 2024