Rating | 80 deg C, 300 Vac Cable flame. |
|
Conductor | 40 AWG minimum, solid or stranded. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together to form a round cable. A flat or oval cable may also be constructed with not more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; PET; thermoplastic covering or thermoplastic tape wrap. The barrier layer may be applied over the twisted assembly of individual conductors, groups of conductors or individual conductors or over the shield, if provided. |
|
Shield | Optional. Location not specified. |
|
Jacket | Extruded PUR. |
| *Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.700 inch or less | 30 mils | 24 mils |
| 0.701-1.000 inch | 45 mils | 36 mils |
| 1.001-1.500 inch | 60 mils | 48 mils |
| 1.501-2.500 inch | 80 mils | 64 mils |
| 2.501-4.000 inch | 110 mils | 88 mils |
| 4.001 inch and larger | 140 mils | 112 mils |
| *Major dia if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment.
or
Internal wiring or external interconnection of
electronic equipment in abuse areas.
|
|