APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21529 Issued:2006-12-08
Revised:2012-03-13
Style 21529 Multiple-conductor cable using non-integral jacket.

Rating90 deg C, 300 Vac, Cable flame.
Conductor26 AWG minimum. Solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure.
ShieldOptional.
CoveringOptional inner layer.
JacketExtruded TPE.
Diameter of core assembly under jacketMinimum average thicknessMinium thickness at any point
0.700 or less inch45 mils36 mils
0.701-1.000 inch60 mils48 mils
1.001-1.500 inch80 mils64 mils
1.501-2.500 inch110 mils88 mils
2.501 and larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor electronic equipment or appliance as internal or external.