APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21533 Issued:2007-02-06
Revised:2011-10-03
Style 21533 Multiconductor Cable Employing Heat Sealed PET Tape Outer Covering.

Rating80 deg C, 30 Vac, Horizontal flame.
ConductorLabeled or complying with Manufacturer's AWM Procedurehaving a minimum rating of 80 deg C and 30 Volts.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyConsists of two or more insulated conductors. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly.
CoveringOptional
ShieldOptional.
CoveringOuter, required - heat sealed PET tape. Minimum 1 mils thick.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring and for further processing in jacketed multiconductor cables.