APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21537 Issued:2007-02-19
Revised:2011-08-11
Style 21537 Multiple-Conductor Cable with Extruded Non-Integral Jacket

Rating80 deg C, 300 Vac, Horizontal flame
Conductor33 AWG - 10 AWG solid or stranded
InsulationExtruded FEP
Conductor size AWGMinimum average thicknessMinimum thickness at any point
33-15 AWG9 mils8 mils
14-10 AWG15 mils13 mils
AssemblyTwo or more insulated singles. Barrier layer and/or fillers optional. Two or more jacketed cables may bond together to form a flat cable. Separable construction.
ShieldOptional
CoveringOptional
JacketExtruded PVC, 20 mils minimum average thickness, 16 mils minimum thickness at any point
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseInternal wiring

UL and the UL Logo are trademarks of UL LLC © 2025