|
Rating | 90 deg C, 300 Vac, Horizontal flame (construction A only). |
|
Conductor | 36 AWG - 20 AWG min. Resistance Wire. |
|
Insulation | Extrudded ETFE, 9 mils minimum average thickness, 8 mils minimum at any point |
|
Assembly | 2-6 individually insulated conductors or groups of conductors cabled together into a round cable. |
|
Shield | Braid (85 percent min coverage tinned or bare copper or stainless steel). Over the individual or groups of conductors. |
|
Covering | Construction A: XLFRLPE, 9 mils minimum average thickness, 7 mils minimum thickness at any point. Construction B: XLPE, 9 mils minimum average thickness, 7 mils minimum thickness at any point. |
|
Braid | Optional. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | CONSTRUCTION A: Internal Wiring, High Resistance Heater Wire. CONSTRUCTION B: For Further Processing, High Resistance Heater Wire.
|
|