| Rating | 90 deg C, 300 Vac, Horizontal flame (construction A only). |
|
| Conductor | 36 AWG - 20 AWG min. Resistance Wire. |
|
| Insulation | Extrudded ETFE, 9 mils minimum average thickness, 8 mils minimum at any point |
|
| Assembly | 2-6 individually insulated conductors or groups of conductors cabled together into a round cable. |
|
| Shield | Braid (85 percent min coverage tinned or bare copper or stainless steel). Over the individual or groups of conductors. |
|
| Covering | Construction A: XLFRLPE, 9 mils minimum average thickness, 7 mils minimum thickness at any point. Construction B: XLPE, 9 mils minimum average thickness, 7 mils minimum thickness at any point. |
|
| Braid | Optional. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|