APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21543 Issued:2007-04-13
Revised:2012-02-06
Style 21543 Parallel Cable.

Rating80 deg C, 30 Vac, Cable flame.
AssemblyTwo or more jacketed cables are laid parallel and heat bonded together to form a flat cable. One or more PVC-covered, nylon Hollow Tubes may be heat bonded between or on the side of the jacketed cables. If the cable construction is rippable, measurements of jacket thickness shall be made after ripping.
CoveringOuter layer - PVC extruded over Nylon Hollow Tubes. Thickness same as one of labeled PVC jacket
JacketLabeled or complying with manufacturer's AWM procedure with minimum ratings of 80 C, 30 V.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024