Rating | 80 deg C, 30 Vac, Cable flame. |
|
Assembly | Two or more jacketed cables are laid parallel and heat bonded together to form a flat cable. One or more PVC-covered, nylon Hollow Tubes may be heat bonded between or on the side of the jacketed cables. If the cable construction is rippable, measurements of jacket thickness shall be made after ripping. |
|
Covering | Outer layer - PVC extruded over Nylon Hollow Tubes. Thickness same as one of labeled PVC jacket |
|
Jacket | Labeled or complying with manufacturer's AWM procedure with minimum ratings of 80 C, 30 V. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External wiring. |
|