APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21548 Issued:2007-04-17
Revised:2012-04-18
Style 21548 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor33-10 AWG. Solid or stranded.
InsulationExtruded ETFE
Conductor sizeMinimum average thicknessMinimum thickness at any point
33-15 AWG9 mils8 mils
14-10 AWG15 mils13 mils
AssemblyTwo or more individually jacketed singles laid parallel and bonded together to form a flat cable.
CoveringOptional.
ShieldOptional.
JacketExtruded PVC, 20 mils minimum average thickness, 16 mils minimum thickness at any point, thickness measured after split.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.